Units are available from stock to 6 weeks. The 437 is backed by Calex’s five year warranty. Calex offers a mounting kit for use in DIN Rail applications. 25 mV select 10 mV switches 3, 4, and 12.5 mV must be ON.

Calex model 6255 full#

The unit is completely encapsulated for use in rugged environments. 6255 Full Bridge Strain Gage or Single Ended 1000 megohms differential 10 nA maximum 0.02 of Full Scale to +5.5 Volts Sw itch Position Full Scale Input Switch positions shown must ALL up to the Range desired, i.e. The Model 437’s excitation supply is capable of driving four 350 ohm load cells. This unit also has a bridge balance with an 80% tare offset capability. This model employs a high gain amplifier which can accept full scale live load signals as low as 5 mV and provide a 16 mA output span. The built-in 10V excitation supply is capable of driving a 350-ohm bridge. The 0 mV to 50-mV input range makes it compatible with most strain-gage-based load-cell or pressure-transducer outputs. it emits thermal (visible and infrared) energy. The 6255 provides a cost-effective solution for applications such as conveyor weighing systems, hoppers or tank farms. It consists of a heated (or cooled) target object whose temperature is precisely known, and is the basis for accurate calibration of infrared pyrometers. Also turning on to many switches on the 6255’s built in amplifier can damage or destroy the module. Doing this will possibly damage or destroy the 6255. This could happen if you had an original BD blender with the 8555 and ordered a replacement Calex module. The Model 437 provides an isolated 4-20 mA or 0-20 mA output capable of driving a 1000 ohm loop. A blackbody calibration source is a tool for checking the calibration of an infrared temperature sensor. WITH AN EXTERNAL ACS AMPLIFIER (remove it and wire loadcell directly to the Calex 6255). It has a Bridge Balance pot and high gain capability to accurately condition load cell weighing systems with large tare offsets and small live load signals.

calex model 6255

It contains a precision instrumentation amplifier with an isolated, filtered output and a highly regulated, low noise, adjustable output bridge excitation source. The Model 437 is a self-contained, DC powered signal conditioner for load cells and transducers utilizing full bridge strain gages. JCalex announces the Calex Model 437 signal conditioner. Calex announces Model 437 signal conditioner













Calex model 6255